Cable fire ratings are not interchangeable. VW-1 is a small-scale vertical-wire flame test described in UL 1581. CMP (plenum) communications cable is evaluated for flame spread and smoke using a method such as NFPA 262. CMR (riser) cable is evaluated for vertical flame propagation in a shaft test such as UL 1666. NFPA 70, the National Electrical Code, then sets where each listed type may be installed. A VW-1 result does not make a cable plenum-rated, and a plastics rating such as UL 94 is not a cable listing.
This article compares the ratings buyers ask about most often and how to specify them. It does not claim that any plant, including ours, holds these listings, and it is not installation advice.
Cables can run through concealed spaces, vertical shafts, and air-handling plenums. The concern is not only whether a single wire goes out after a small flame is removed, but whether fire and smoke can travel along a bundle or through a building path. That is why North American practice uses a ladder of listed types rather than a single "flame retardant" phrase.
For communications cable, the usual ladder, from more limited to more demanding, is:
A higher rating is generally acceptable in a less demanding location; a lower rating is not a substitute in a more demanding one, unless the cable is installed by a method the code allows (for example, in a raceway that the code accepts in that space). Always follow the edition of the NEC adopted by the authority having jurisdiction.
Coaxial / CATV cables use a parallel set of type letters (CATVX, CATV, CATVR, CATVP). Other families use their own prefixes, such as CL2P / CL3P for power-limited circuit cable. The letter after the family—X, none, R, or P—is the fire-use cue.
VW-1 is a vertical specimen flame test in UL 1581, Reference Standard for Electrical Wires, Cables, and Flexible Cords. A National Institute of Standards and Technology review of cable fire tests, NIST Technical Note 1291, identifies the UL 1581 vertical-wire flame test (VW-1) as the method associated with limited-use types such as CMX, and notes that it uses a small burner and does not measure smoke.
Treat VW-1 as what it is: a limited, small-scale test on a specimen. It is useful when a specification calls for it, and it is a common mark on appliance and hook-up wires. It is not evidence that the same cable may be installed exposed in a riser or a plenum.
CMR is the communications riser type in the NEC Article 800 family. It is intended for vertical runs in a shaft or for installations that penetrate more than one floor, subject to the code rules for that space. The associated test is a vertical shaft flame-propagation test, commonly UL 1666.
CMR addresses flame travel up a vertical path. It does not, by itself, impose the smoke limits used for plenum cable. If the run is in an air-handling plenum and the cable will be exposed, CMR is the wrong type unless the installation method the code allows for a non-plenum cable is actually being used.
CMP is the communications plenum type. Cables of this type are listed for use in ducts, plenums, and other environmental air spaces as the code permits, because they have been evaluated for fire-resistant and low-smoke characteristics. The test method widely referenced today is NFPA 262 (the Steiner-tunnel method that succeeded UL 910 for this application).
UL Solutions summarizes the NFPA 262 criteria as a maximum flame-spread distance of 5 ft, a maximum peak optical density of 0.5, and a maximum average optical density of 0.15. Use that summary as a guide to why plenum tests are stricter than VW-1 or a riser test, then confirm the listing against the standard and the laboratory directory.
The same idea applies to CATVP for coaxial / CATV cable and to other "P" types. For how those marks show up on a specification, and what a listing file should prove, see Which Certifications Apply to Plenum-Rated Communications Cable, and Where Is It Used?.
If a drawing mixes these terms, ask which listed cable type is required for the installation.
Name four things, in plain language:
Substance restrictions such as RoHS and REACH are separate from fire ratings. Call them out separately if the program needs both.
Does a VW-1 rating mean the cable can go in a plenum? No. VW-1 is a small-scale vertical-wire test. Exposed use in an air-handling plenum requires a plenum-listed type such as CMP or CATVP, or another method the code permits.
Can CMP cable be used in a riser? Typically yes, because the plenum rating is the more demanding fire-and-smoke rating, but the installation must still follow the adopted NEC rules and the listing. CMR cannot be assumed to replace CMP in an exposed plenum.
Is UL 94 V-0 the same as VW-1 or CMP? No. UL 94 rates a plastic material sample. VW-1 and CMP are tests or listings that apply to cable (or, for CMP, to a listed cable type). Do not treat a material Yellow Card as a cable type mark.
What does the "P" or "R" in CMP and CMR stand for? In this family, P is the plenum type and R is the riser type. The letters in front (CM, CATV, CL2, and so on) identify the cable family.
Which rating should be written on the drawing? Write the listed type required by the installation (for example CMP or CMR), the test method if you need to name it, and a requirement to supply a current listing for that construction.
Send us the cable specification and the fire rating or listed type you need, and our team will review your RFQ.